HYCRUI8S-A1
CSQ
HYCRUI8S-A1 monitoring relay adopts the special chip sampling AC technology, which can measure the single phase, voltage (frequency) current in the power grid, and set the overvoltage and undervoltage current values according to the site conditions, so that the power consumption of the terminal equipment can be controlled. Mainly used for over/undervoltage and over/undercurrent of electrical equipment.
Model | HYCRUI8S-A1 | |||
Features | Single Phase AC Voltage & Current | |||
Output contact | 1 set of 10/16A (if only monitoring is required and no output contacts are required, add 0 after the model number, for example: HYCRUI8S-A10) | |||
Operating voltage | AC24-240V(50-60Hz)/DC24-240V | |||
Indicator light | Work indication: Green LED0.5S flashing, relay indication: R red LED real-time indication | |||
Setting method | Digital display, button adjustment, voltage setting accuracy1,current setting accuracy 0.1 | |||
Detection range | Voltage 24-240V (AC measurable frequency 40-65Hz) / single-phase current 0.02-16A (current can be expanded by external current transformer) | |||
Limit range | ±10% (single phase voltage 22-275V/single phase current 0.02-20A) | |||
Delay time | Power on delay time: 0.5-29.9S | |||
Recovery value | 3-19% | |||
Detection accuracy | Voltage: ±1V below 100V, ≤1% above 100V; Current: ≤1%; Temperature fluctuation error <0.05%/℃ | |||
Reset time | <1S | |||
Contact capacity | 10/16A(AC1 Resistive) | |||
Mechanical life | 1x105 (Resistive load, room temperature, 1s on and 9s off) | |||
Environment | Working temperature: -10-55℃ Relative humidity: ≤85% Altitude: ≤2000 meters Storage temperature: -20-75℃, no rain, snow, salt fog and corrosive gas | |||
Installation method | 35mm din rail type |
HYCRUI8S-A1 monitoring relay adopts the special chip sampling AC technology, which can measure the single phase, voltage (frequency) current in the power grid, and set the overvoltage and undervoltage current values according to the site conditions, so that the power consumption of the terminal equipment can be controlled. Mainly used for over/undervoltage and over/undercurrent of electrical equipment.
Model | HYCRUI8S-A1 | |||
Features | Single Phase AC Voltage & Current | |||
Output contact | 1 set of 10/16A (if only monitoring is required and no output contacts are required, add 0 after the model number, for example: HYCRUI8S-A10) | |||
Operating voltage | AC24-240V(50-60Hz)/DC24-240V | |||
Indicator light | Work indication: Green LED0.5S flashing, relay indication: R red LED real-time indication | |||
Setting method | Digital display, button adjustment, voltage setting accuracy1,current setting accuracy 0.1 | |||
Detection range | Voltage 24-240V (AC measurable frequency 40-65Hz) / single-phase current 0.02-16A (current can be expanded by external current transformer) | |||
Limit range | ±10% (single phase voltage 22-275V/single phase current 0.02-20A) | |||
Delay time | Power on delay time: 0.5-29.9S | |||
Recovery value | 3-19% | |||
Detection accuracy | Voltage: ±1V below 100V, ≤1% above 100V; Current: ≤1%; Temperature fluctuation error <0.05%/℃ | |||
Reset time | <1S | |||
Contact capacity | 10/16A(AC1 Resistive) | |||
Mechanical life | 1x105 (Resistive load, room temperature, 1s on and 9s off) | |||
Environment | Working temperature: -10-55℃ Relative humidity: ≤85% Altitude: ≤2000 meters Storage temperature: -20-75℃, no rain, snow, salt fog and corrosive gas | |||
Installation method | 35mm din rail type |