Availability: | |
---|---|
HYCRT8-A3
CSQ
HYCRT8-A3 single function timer relay is a settable time control unit. Combined with other electrical equipment, it can set delay closing or delay opening contacts according to the required time, so that the working time of terminal equipment can be controlled. Mainly used in industrial equipment, lighting, manufacturing and other occasions requiring time control.
Model | HYCRT-A1/B1 | HYCRT-A2/B2 | HYCRT-A3/B3 |
Features | Type A: Power-On delay Type B: Delay disconnect | ||
Output configuration | One set of delay | Two sets of delay | One set of delay plus one set of instantaneous |
Operating voltage | AC24-240V(5060Hz)/DC24-240V voltage fluctuation ±10% | ||
AC220V(50-60Hz) voltage fluctuation ±20% | |||
Indicator light | Work indication: Green LED0.5S flashing, relay indication: R1 red LED real-time indication | ||
Delay setting method | Rotary adjustment | ||
Delay range | 0.1S-10d (0.1 seconds-10 days), adjustable in multiple gears | ||
Delay accuracy | <1% Basic error <1%, mechanical error <10%, repeat error <0.5%, Temperature fluctuation error <0.05%/℃, voltage jump error <1% | ||
Reset time | <500ms | ||
Output contact capacity | AC/DC24-240V Power supply | 10/16A (AC1-Resistive) | |
AC220V Power supply | 3/5A (AC1-Resistive) | ||
Mechanical life | 1x105 (Resistive load, room temperature, 1s on and 9s off) | ||
Environment | Working temperature: -10-55℃ Relative humidity: ≤85% Altitude: ≤2000 meters Storage temperature: -20-75℃, no rain, snow, salt fog and corrosive gas | ||
Installation method | 35mm Din rail type |
HYCRT8-A3 single function timer relay is a settable time control unit. Combined with other electrical equipment, it can set delay closing or delay opening contacts according to the required time, so that the working time of terminal equipment can be controlled. Mainly used in industrial equipment, lighting, manufacturing and other occasions requiring time control.
Model | HYCRT-A1/B1 | HYCRT-A2/B2 | HYCRT-A3/B3 |
Features | Type A: Power-On delay Type B: Delay disconnect | ||
Output configuration | One set of delay | Two sets of delay | One set of delay plus one set of instantaneous |
Operating voltage | AC24-240V(5060Hz)/DC24-240V voltage fluctuation ±10% | ||
AC220V(50-60Hz) voltage fluctuation ±20% | |||
Indicator light | Work indication: Green LED0.5S flashing, relay indication: R1 red LED real-time indication | ||
Delay setting method | Rotary adjustment | ||
Delay range | 0.1S-10d (0.1 seconds-10 days), adjustable in multiple gears | ||
Delay accuracy | <1% Basic error <1%, mechanical error <10%, repeat error <0.5%, Temperature fluctuation error <0.05%/℃, voltage jump error <1% | ||
Reset time | <500ms | ||
Output contact capacity | AC/DC24-240V Power supply | 10/16A (AC1-Resistive) | |
AC220V Power supply | 3/5A (AC1-Resistive) | ||
Mechanical life | 1x105 (Resistive load, room temperature, 1s on and 9s off) | ||
Environment | Working temperature: -10-55℃ Relative humidity: ≤85% Altitude: ≤2000 meters Storage temperature: -20-75℃, no rain, snow, salt fog and corrosive gas | ||
Installation method | 35mm Din rail type |
Hangzhou Office Address:
13th Floor,Building 6, Huacai International, Xihu District, Hangzhou City,China
Wenzhou Factory Address:
No. 198, Wei 3rd Road, Economic Development Zone Of Yueqing, Wenzhou city, China
+86-577-61737670