Views: 72 Author: Site Editor Publish Time: 2022-10-06 Origin: Site
The time relay is a set table time control unit.Combined with other electrical equipment, according to the required time and function,set the delayed closing or delayed opening contacts, so that the working time of the equipment can be controlled.
Industrial equipment, lighting control, manufacturing and other occasions requiring time control.
1. AC24-240V(50-60Hz/DC24-240V Voltage fluctuation ± 10%
2. AC220V(50-60Hz)Voltage fluctuation ± 20%
Maybe you need: time delay relay 24v, 110 volt time delay relay, timer relay 120v, 220v timer relay, 240 volt time delay relay, ac time delay relay, dc timer relay
0.1S-99H(0.1seconds-99hours),button adjustable
Maybe you need: 5 second timer relay, 30 second timer relay, 10 minute timer relay, 24 hour timer relay, 7 day timer relay, cyclic timer relay
35mm Din rail type
Function A:
Delayed closing mode-R is closed after a delay of t, S closed signal is received(S falling edge trigger), R is disconnected, the delay starts after the S signal is disconnected, and S is closed again within the delay range Disconnect the signal to restart the delay.
Function B:
Delayed closing mode-R is closed after a delay of t, s closed signal is received(S falling edge trigger), R is disconnected the delay starts after the S signal is disconnected, and S is closed again Within the delay range-The disconnection signal does not act , and it needs to restart after the last delay is completed.
Function C:
Delay disconnection mode-R is disconnected after a delay of t , and S closed signal is received(S falling edge trigger R is closed,and the delay starts after the S signal is disconnected and s close is received again within the delay range-Disconnect the signal to restart the delay.
Function D:
Delay disconnection mode-R is disconnected after delay t and S signal is detected to be closed(S rising edge trigger), R is closed and starts to delay, when S signal is detected again,it will not act,and the last delay is required.start again after completion.
Function E:
Delay disconnection mode-R is disconnected after a delay of t ,closed after receiving the S signal (triggered by the falling edge of s),R is closed , and the delay starts after the S signal is disconnected, and S is closed again within the timing range-The disconnection signal does not act and it needs to restart after the last delay is completed.
Function F:
Single function cycle mode-(S falling edge trigger) detected S closed-disconnected signal to restore the default state and re-delay, t-R closed -t -R open-t-R closed...
Function H:
Single-function cycle mode-(S falling edge trigger). detected S closed-disconnected signal to restore the default state and re-time, t-R open -t -R closed -t -R open....
Function L:
On-off delay mode-after S is closed for t delay .R is closed,S is disconnected,and after delay t, R is disconnected.
Function N:
Pulse output mode-t delay R is closed for 0.5S and then R is disconnected.When S is detected to be closed-disconnected the signal returns to the default state and delays again.
Function O:
Bistable mode(pulse conversion)- S closed signal R state conversion,the delay in this mode has no effect ,and it is useless to directly rotate NO and OFF.
Hangzhou Office Address:
13th Floor,Building 6, Huacai International, Xihu District, Hangzhou City,China
Wenzhou Factory Address:
No. 198, Wei 3rd Road, Economic Development Zone Of Yueqing, Wenzhou city, China
+86-577-61737670